BNLDS - TIN/ANTIMONY SOLDER ALLOY (FABRICATIONS/FOR

  • MSDS: BNLDS
  • Manufacturer: TARACORP INDUSTRIES INC
  • Product Name: TIN/ANTIMONY SOLDER ALLOY (FABRICATIONS/FOR
  • National Stock Number: 3439-00N026805
Product Identification

Product ID:TIN/ANTIMONY SOLDER ALLOY (FABRICATIONS/FOR
MSDS Date:01/01/1989
FSC:3439
NIIN:00N026805
MSDS Number: BNLDS

Responsible Party
TARACORP INDUSTRIES INC
16TH AND CLEVELAND BLVD
GRANITE CITY, IL 62040
US

Emergency Phone: 618-451-4400;800-424-9300(CHEMTREC)

Info Phone: 618-451-4400

Cage: 27177

Contractor
TARACORP INDUSTRIES, EVANS METAL DIV
ATLANTA, GA 30324-4126 US

Telephone: 800-241-4590

Cage: 27177

Ingredients

LIMIT VALUES (TLV'S) SPECIFIED BY OSHA OR OTHER

RTECS: 9999999ZZ


AREAS. PRACTICE GOOD PERSONAL HYGIENE

RTECS: 9999999ZZ


APPLYING COSMETICS OR USING TOBACCO PRODS. AVOID

RTECS: 9999999ZZ


OR FUME. KEEP MELTING/SOLDERING TEMPS AS LOW AS

RTECS: 9999999ZZ


TIN

CAS: 7440-31-5

RTECS: XP7320000

Fraction By Weight: 90-98%

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3


ANTIMONY

CAS: 7440-36-0

RTECS: CC4025000

Fraction By Weight: 2-10%

OSHA PEL 0.5 MG/M3 (SB)

ACGIH TLV: 0.5 MG/M3 (SB)

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


LIVER & KIDNEY DAM & CNS DISORDERS. ANTIMONY CAN

RTECS: 9999999ZZ


NIOSH/MSHA APPROVED RESP PROT WHERE SIGNIFICANT

RTECS: 9999999ZZ


THE PURCHASER ESTABLISH A SPILL PREVENTION, CONTROL &

RTECS: 9999999ZZ


FOR PROPER STORAGE AS WELL AS CLEAN-UP OF

RTECS: 9999999ZZ


FOR PROPER RECOVERY AND/OR DISP. DEPENDING ON

RTECS: 9999999ZZ


CENTER (800-424-8802) MAY BE REQD IN CASE OF HAZ

RTECS: 9999999ZZ


INDUST HYGIENISTS, IS RECD TO MAINTAIN EXPOS LEVELS

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: OVEREXP TO TIN CAN CAUSE IRRIT
OF EYES, SKIN, MUC MEMBRANES & RESP SYS. ACUTE OVEREXP TO ANTIMONY
CAN CAUSE UPPER RESP TRACT IRRIT & SYSTEMIC ANTIMONY POISONING
W/SYMPS INCLUDING ABDOMINAL CRAM PS, NAUS, DIZZ, DRY THROAT &
VARIOUS NERVS COMPLAINTS, SUCH AS SLEEPLESSNESS, IRRITABILITY &
MUSCULAR (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:PAINS. RPTD SKIN CONT W/ANTIMONY MAY
RESULT IN DERM, & EYE CONT MAY CAUSE SEV IRRIT. CHRONIC: OVEREXP TO
TIN CAN RESULT IN BENIGN PNEUMOCONIOSIS (STANNOSIS). THIS FORM OF
PNEUMOCONIOSIS PRODU CES PROGRESSIVE X-RAY CHANGES OF LUNGS AS LONG
AS EXPOS EXISTS, BUT THERE IS NO DISTINCTIVE FIBROSIS, NO (SUPP
DATA)
Medical Cond Aggravated by Exposure:PRE-EXISTING CONDITIONS OF THE
LUNGS, DISEASES OF THE KIDNEYS, LIVER AND NERVOUS SYSTEMS.

First Aid

First Aid:SKIN: NORMAL HYGIENE PROCEDURES - WASH W/SOAP & WATER. IF
IRRIT/RASH DEVELOPS OR PERSISTS GET MEDICAL ATTN. EYES: FLUSH WELL
W/RUNNING WATER FOR AT LEAST 15 MINUTES TO REMOVE PARTICULATE. IF
IRRITATIO N PERSISTS GET MEDICAL ATTENTION. INHAL: REMOVE FROM
EXPOSURE. GET MEDICAL ATTENTION. INGEST: GIVE WATER; INDUCE
VOMITING IN A CONSCIOUS INDIVIDUAL; GET MEDICAL ATTENTION.

Fire Fighting

Flash Point:NON-FLAMMABLE
Extinguishing Media:NO SPECIFIC AGENTS RECOMMENDED. USE MEDIA SUITABLE
FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THE SOLID METAL FORM IS NOT A FIRE
HAZARD. HOWEVER, DUST GENERATED FROM PROCESSING OPERATIONS MAY
PRESENT A MODERATE FIRE OR EXPLOSION HAZARD.

Accidental Release

Spill Release Procedures:1)MATL IN DUST FORM - MINIMIZE EXPOS. CLEAN UP
USING DUSTLESS METHODS (I.E. VACUUM). DO NOT USE COMPRESSED AIR.
2)PLACE IN CLSD LABELED CNTNRS FOR RECYCLING/DISP. 3)KEEP OUT OF
WATERWAYS. NOTE: CLEANU P PERS SHOULD WEAR PROT CLTHG & (ING 4)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:PRACTICE GOOD HOUSEKEEPING PROCEDURES
TO PVNT DUST ACCUMULATIONS. KEEP MATL DRY. AVOID STORAGE NEAR
INCOMPATIBLE MATERIALS.
Other Precautions:KEEP PRODUCT AWAY FROM CHILDREN AND THEIR
ENVIRONMENT. SPECIAL ATTENTION IS DRAWN TO THE REQS OF THE
RESPIRATOR STANDARD (1910.134) SHOULD AIRBORNE EXPOSURES EXCEED THE
OSHA PEL.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATORY PROTECTION IS
REQD WHERE AIRBORNE EXPOSURES EXCEED OSHA/ACGIH PERMISSIBLE AIR
CONCENTRATIONS. RESPIRATOR SELECTION SHALL BE MADE I/A/W THE
RESPIRATORY PROT STANDARD, 29 CFR, 1910.134.
Ventilation:VENT AS DESCRIBED IN "INDUST VENT, & MANUAL OF RECD
PRACTICE" BY THE AMERICAN CONFERENCE OF GOVERNMENTAL (ING 9)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:SAFETY EQUIPMENT SHOULD BE WORN AS
APPROPRIATE FOR THE WORK ENVIRONMENT.
Work Hygienic Practices:DO NOT PERMIT EATING/DRINKING/THE USE OF
COSMETICS OR TOBACCO PRODS WHILE HANDLING/PROCESSING MATL/IN WORK
(ING 11)
Supplemental Safety and Health
BP:TIN, 2260C; ANTIMONY, 1380C. MP:TIN, 232C; ANTIMONY, 1380C. HAZ
DECOMP PROD: ACID/BASE PLUS AN ACTIVE METAL, OR IN PRESENCE OF
NASCENT HYDROGEN, HIGHLY TOXIC STIBINE GAS (TLV=0.10 PPM) MAY BE
EVOLV ED. HLTH HAZ:EVIDENCE OF DISABILITY & NO SPECIAL COMPLICATING
FACTORS. CHRONIC OVEREXP TO ANTIMONY CAN LEAD TO (ING 3)

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:SUPP DATA
Melt/Freeze Pt:M.P/F.P Text:SUPP DATA
Spec Gravity:5.77-5.84
Solubility in Water:INSOLUBLE
Appearance and Odor:SOLID - SILVER TO SILVER-GRAY METALLIC METAL - NO
ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
CHLORINE, TURPENTINE. STRONG ACIDS, BASES, NASCENT HYDROGEN, REDUCING
AGENTS, CHLORINE, FLOURINE AND BROMINE.
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:AT TEMPS ABOVE MELTING POINT METAL
OXIDE FUMES MAY BE EVOLVED. UNDER REDUCING CONDITIONS, SUCH AS ANY
STRONG (SUPP DATA)

Disposal

Waste Disposal Methods:MAY HAVE VALUE ON A RECYCLED BASIS. IF DISPOSED
OF, DISPOSE OF IN A PERMITTED DISPOSAL SITE I/A/W ALL FEDERAL,
STATE AND LOCAL DISPOSAL OR DISCHARGE REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.